Jupiter Breath Alcohol Analyser

Product feature

  • Built-in Printer, GPS
  • 3G/WIFI
  • 16,000 tests records stored in memory (expendible to 32,000)
  • 3.2″ Touch Screen
  • LED Light indicate where to insert mouthpiece
  • Mouthpiece can be automatically ejected
  • USB PC connection
SPECIFICATIONS
Sensor: Fuel Cell
Working Temperature: -10°C to 50°C
Storage Temperature: -25°C to 70°C
Size: 19.5m x 7.90cm x 3.5cm
Weight: 433g included battery
Batter/ Life: over 1,500 tests (over 150 test with printouts)
Battery: 7.4V 1800mAh NiMH rechargeable battery
Display LCD Size: 32′ TFT Colour touch screen (65.000 colours)
Sampling System: Automatically or manually lakes a lung sample
Optional Power: Supply 12-volt car adapter or AC 6 v adapter
Clock: Real time clock
Unit of Measure: BrAC: mg/L, or other units BAC: grm%. Mg/mL, mg/100ml. or other units
Detection Range: 0.0% BAC lo 0.40% BAC
Accuracy: 0 – 0.10% BrAC ±5%, 0.10-0.15% BrAC±8%, >0.15%: ±10%
Memory: 16000 tests records, inducing all information, extendable to 32,000 records)
GPS: ±5M
Connection Port: USB
Printer: Thermal printer
breath-alcohol-analyzers

Jupiter-X Breath Alcohol Analyser

Product feature

  • Built-in Printer, GPS
  • 3G/WIFI
  • Photo capture
  • Provide evidential records by auto capturing while subject blowing
  • 100,000 tests. records stored in memory
  • 4.3”Color Touch Screen
  • API can be provided
  • Mouthpiece can be automatically ejected
  • USB PC connection
SPECIFICATIONS
Sensor: Fuel Cell
Wireless Communication: 3G, WiFi
Working Temperature: (-10°C to 50°C)
Size: 21.2cm X Scm X 3.6 cm
Weight: 423g Included battery
Storage Temperature: (-30°C to 70°C)
Battery Life: 3,000 tests Battery 7 4V 1800mAh Nl-MH rechargeable battery
Display: LCD size 4.3″ TFT colour touch screen Sampling System Automatically or manually takes a deep lung sample Optional
Power Supply: 12V Car adapter or AC 6 V adapter
Camera: 3.0 megapixel 120° wide angle Lens
Units of Measure: BrAC: mg/L, or other units, BAG: grm%, mg/ml, mg/100 ml, or other units
Detection Range: 0.00% BAC to 0.40% BAC
Accuracy: 0-0.10%. BrAC ±5%, 0.10-0.15% BrAC ±8%, >0.15%: ±10%
Memory: 100,000 tests records including all information
SD Card: provide a standard 2GB SO (support up to 16GB)
GPS: ±5M
Connection Port: USB
Printer: Thermal printer